Description
Technical Specifications
| Wavelength | Angle |
|---|---|
| 850nm | 10º – Circular 30º – Elliptical 60º – Elliptical 95º – Elliptical |
| 940nm | 10º – Circular 30º – Elliptical 60º – Elliptical 95º – Elliptical |
| ELECTRONICS | High efficiency surface mount high power dual core® with advanced current limited integral control circuitry |
| CONSTRUCTION | Robust high quality aluminium extrusion |
| FRONT WINDOW | Polycarbonate high transmission protective (vandal proof) ir filter with CleanLITE® technology |
| FINISH | Black anodised |
| POWER CABLE | 3m (9ft) including photocell following contact & remote telemetry input |
| PRESSURE EQUALISATION VENT |
Prevents thermal expansion & pressure cycling |
| PHOTOCELL | Adjustable 20 -70 Lux |
| ILLUMINATION | Adjustable 10% – 100% |
| OPERATING TEMPERATURE | -50° to 50ºC (-58º to 122ºF) |
| WEIGHT | 1.05Kg (2.3lbs) |
| MOUNT | Powder coated stainless steel wall mount |
| DIMENSIONS | 114 x 110 x 78mm (4.49” x 4.33” x 3.07”) |
| INPUT VOLTAGE | 12-32V DC or 24V AC +/-10% |
| INPUT CURRENT | 1.2A at 24V AC |
| CONSUMPTION | 26W |
| STANDARD | 850nm (Semi Covert). Faint Red Glow Only |
| OPTIONAL | 940nm (Covert). Minimal visible glow |
| WEEE | Waste electrical & electronic equipment european directive 202/96/EC |
| RoHS | Restriction of hazardous substance european directive 202/95/EC |
| CE-EMC | EN 61547 (Lighting-Immunity) EN 55015 (Lighting-Emission) EN 62493 (Lighting-EMF) EN 50130-4 (Alarm-EMC) |
| CE-LVD | EN 60598-1 (Luminaires-General) EN 60598-2-1 (Luminaires) EN 62368-1 / EN 60950-22 |
| SAFETY | EN 62471 (LED safety) |
| ENVIRONMENTAL | IEC/EN 60529 IP66 IEC/EN 62262 IK09 EN 50130-5 (Alarm-environmental) N2580, EN 50581 (RoHS), REACH |
| USA | cULus UL 2108 UL 8750 FCC Class B |
| AUS | RCM (AS/NZS CISPR 22 Class B) |


Reviews