Skip to content

Order now for delivery Tuesday 27 October on orders over £300 mainland UK

Kratos

Kratos N270 3000va/2700W on-line Double Conversion UPS

SKU UPS-NEMESIS-N270

Out of stock

£1,286.40 ex VAT

£1,543.68 inc VAT

This UPS is either rack mountable or a free standing tower unit. it has a PFC (power factor correction) of 0.9pfc (dependant on input volatage). As an online UPS this offers protection from power surges and spikes as the current is first flowed through the batteries and then to the connected equipment thus offering a higher level of protection than standard line interactive UPS's. Greater back up time can be achieved with the use of external battery packs.

Key specifications

Model
Nemesis N90
Input
Voltage**
Frequency
45-65Hz (Auto Sensing)
Power Factor
≥0.99 (Full Linear Mode)
Generator Input
Supported
Input Connection
10A, IEC 320-C14
Capacity
N90/N180/270 when input voltage is 210~240Vac PF=0.9(900/1800/2700W) when input voltage is 185~260Vac PF=0.8(800/1600/2400W) when input voltage is 160~300Vac PF=0.7(700/1400/2100W)
Output
Voltage
Full specification

Description

This UPS is either rack mountable or a free standing tower unit. it has a PFC (power factor correction) of 0.9pfc (dependant on input volatage). As an online UPS this offers protection from power surges and spikes as the current is first flowed through the batteries and then to the connected equipment thus offering a higher level of protection than standard line interactive UPS’s. Greater back up time can be achieved with the use of external battery packs.

  • Ensures highest reliability and availability with double conversion and true on-line technology
  • Enables integration with wide variety of site environments with super compact tower/rack convertible design
  • Offers high energy savings with near unity input power factor design
  • Suits various utility requirements with wide input voltage tolerance (120~280V dependant on load)
  • Provides easy reading of major parameters and status on LCD display
  • Provide powerful charging capabilities to re-charge internal battery to 90% in 3 hours
  • Lets you monitor from PC via RS232 communications interface
  • Features customer options slot for SNMP, AS400, volt-free interface
  • Allows quick replacement with easy swappable battery
  • Offers extra long back-up time with various external charger options (up to 3000W)
  • Makes maintenance easy without interrupting the loads with optional external maintenance bypass switch

Technical Specifications

Model Nemesis N90
Input Voltage**
Frequency 45-65Hz (Auto Sensing)
Power Factor ≥0.99 (Full Linear Mode)
Generator Input Supported
Input Connection 10A, IEC 320-C14
Capacity N90/N180/270
when input voltage is 210~240Vac PF=0.9(900/1800/2700W)
when input voltage is 185~260Vac PF=0.8(800/1600/2400W)
when input voltage is 160~300Vac PF=0.7(700/1400/2100W)
Output Voltage
Voltage Regulation Within ±1% until low battery warning
Frequency Sync Range 3Hz or 1Hz selectable
Frequency
(battery Mode)
50/60 Hz 0.1% unless synchronised to the line
Current Crest Ratio 3:1
Harmonic Distortion <3% at full Linear Load, <7% at full Non-Linear Load
Output Waveform Pure Sinewave
Outlets (3)10A, IEC 320-C13
Overload Capacity
(tolerance ±1%)
In Line Mode
210~265VAC Derating PF=0.9
900W/100% 1800W/100%
800W/100% 1800W/100%
700W/100% 1400W/100%
Battery Mode <105% continuous
106-120% for 30 seconds shuts down
121-150% for 10 seconds shuts down
>150% Immediately shuts down
Buzzer continuously alarms
Bypass Mode <105% continuous
106-120% for 250 seconds shuts down
121-130% for 125 seconds shuts down
131-135% for 50 seconds shuts down
136-145% for 20 seconds shuts down
146-148% for 5 seconds shuts down
149-157% for 2 seconds shuts down
158-176% for 1 second shuts down
177-187% for 0.32 of a Buzzer continuously alarms
Model Nemesis N90
Efficiency Line Mode
Battery Mode 85%
ECO Mode 97%
Battery Number of Batteries
Related Battery Voltage 7Ah
Rated Battery Voltage 36VDC
BBaacckk uupp
tt ii mm ee
((LLiinneeaarr LLooaadd))
50% Load
70% Load >3min
100% Load >1min
C h a r g e
current
m a x
Standard
External 3A
Recharge Time (to 90%) 4hr
Floating Mode Charging Voltage 27.4VDC±1%
Bulk Mode Charging Voltage 30VDC±1%
DC Leakage Current ≤30μA with no AC applied and the unit in the off position
Transfer
Time
AC to DC
Inverter to Bypass 4mS (Typical)
DC Start Yes
Self
Diagnosis
Upon Power-on, Front panel settings & software control,
24 hours routine check
Front Panel LCD
Button Fault, Overload and Load/Battery Leve
ON/OFF/Select/Silence
Alarm Battery Mode
Low Battery Sounds once every 0.2 seconds
Overload Sounds once every 3 seconds
Normal alarm Sounds once every 3 seconds
Fault Continuous tone
Protection Short Circuit
Battery Normal Mode: Output Breaker/Electronic Circuit Battery
Mode: Output Breaker/Electronic Circuit
Battery Displacement Management
EPO Shuts down UPS Immediately
Over Temperature Normal Mode : Transfer to bypass mode
Battery Mode: UPS Shuts down immediately
Physical Dimensions (DxWxHmm)
Weight 10kg
Environmental Operating Temperature
Noise Level ≤50dB
Relative Humidity 0-90% (without condensation)
Interface Standard
Option EPO, 2nd RS232, USB, RS485, Dry contacts, SNMP/Web Card
Compatible Platforms Microsoft Windows series, Linux, Mac, etc.
Standards
and
Certifications
Safety
EMC EN62040-2, EN61000-3-2, EN61000-3-3
Marks CE

Additional information

Brand

Kratos

Reviews

There are no reviews yet.

Be the first to review “Kratos N270 3000va/2700W on-line Double Conversion UPS”

Your email address will not be published. Required fields are marked *